Moisture Image Series 1 - Moisture Analyzer

Moisture Image Series 1 - Moisture Analyzer

The Moisture Image Series 1 (MIS 1) analyzer is the top-of-the-line model in GE Panametrics’ family of Moisture Series analyzers. This multifunction analyzer uses charts, graphs and windows to display any of six parameters (moisture, oxygen, temperature, pressure and two auxiliary inputs) for as many as six channels simultaneously on a large, backlit LCD. Real-time data can also be exported to a PC using the instrument’s RS232 port and standard or custom software packages.

Combining the MIS 1 analyzer, the MIS probe, and our nondepleting oxygen cell creates a system capable of measuring as many as six points each of ambient to trace amounts of moisture and oxygen. Computer-enhanced response and a true ppbv scale are included for fast response and maximum resolution and accuracy in extremely low-level measurement applications.

For added flexibility, the analyzer’s auxiliary inputs accept measurements from any sensor with current or voltage output, making the MIS 1 a true multifunction analyzer. Other features include intrinsic safety for all inputs, isolated analog outputs, alarm relays and a built-in 24-VDC power supply for current loops. The instrument is available in rack, bench, panel, weatherproof and explosion-proof packages.

Contact Sales

final_phone2

Get the Moisture
Calculator iPhone app.


Features

  • Absolute humidity in liquids and gases
  • Ambient to ppb moisture and oxygen ranges
  • One to six measurement channels
  • Simultaneous graphic display of six measurements
  • 16-bit moisture measurement resolution
  • Compatible with MISP,TF and M Series type moisture probes
  • Auxiliary inputs for other parameters
  • Computer-enhanced speed of response
  • Intrinsically safe, certified to EEx ia IIC and Class I, Div. 1, All Groups

 

Applications

This multichannel analyzer measures moisture in gases and non-aqueous liquids and oxygen (optional) in gases. Designed for permanent installations, it is used in conjunction with Moisture Image Series, TF and M Series moisture probes for industries including:

• Petrochemical

• Natural gas

• Industrial gas

• Semiconductor

• Furnace gas/heat treating

• Power generation

• Air dryer

• Pharmaceutical

• Aerospace

Specifications

Electronics

Intrinsic Safety Galvanic isolation and energy-limiting circuitry for all inputs (except auxiliary):
BAS01ATEX7097 II (1) G [EEx ia] IIC –20°C to +50°C;
CSA C US Class I, Division 2, Groups B,C&D T4A–Assoc.
Elec. Apparatus [Exia] and Class I, Division 1,Groups A,B,C&D T4
European Compliance Complies with EMC Directive 89/336/EEC and 73/23/EEC LVD (Installation Category II, Pollution Degree 2)
Inputs
  • Moisture: One to six channels
  • Temperature: One to six channels
  • Pressure: One to six channels
  • Oxygen: One to six channels • Auxiliary (optional): Two per installed channel; may be used for 0/4 to 20 mA and 0 to 4 V devices
Analog Outputs Two per channel; internally optically isolated; 10-bit (0.1%) resolution
Programmable Switch-Selectable Outputs
  • 0 to 2 V, 10 S minimum load resistance
  • 0/4 to 20 mA, 400 S maximum series resistance
Digital Outputs RS232 serial communications port; information is transmitted as ASCII
A/D Resolution 12-bit or 16-bit with MIS probe
Computer-Enhanced Response Software Standard: Provides fast measurements in abrupt dry-down applications (three- to five-minute speed of response)
Data Logging Up to 12 parameters simultaneously; stored in RAM; log length depends on number of items and time interval
Memory
  • Standard: Battery-backed 64 kB RAM 
  • Optional: Additional 1 MB (or more) with PCMCIA card
PC-Interface Software Optional: PanaView™ instrument interface software
Alarm Relays
  • Two optional Form C relays per channel SPDT; rated for 2 A at 28 VAC/28 VDC
  • Standard and hermetically sealed (for Division 2 hazardous areas per CSA) available for high and low limits on each channel; set to any level within the range of the instrument
Alarm Set Point Accuracy ±0.1°C dew point
Display Graphic/text backlit LCD
Display Functions Displays up to six channel/parameter combinations simultaneously using text and/or graphics
Power Requirements Universal power supply adjusts automatically for 90 to 260 VAC, 50/60 Hz
Temperature
  • Operating: 32°F to 140°F (0°C to 60°C)
  • Storage: –22°F to 158°F (–30°C to 70°C)
Data Retention Calibration data stored in battery-backed RAM
Autocalibration Occurs on power-up and at user-selected time intervals
Configuration Dimensions (h x w x d)
  • Rack mount: 5.22 x 19.00 x 17.03 in (13.26 cm x 48.26 cm x 43.26 cm)
  • Bench mount: 5.85 in x 13.94 in x 17.03 in (14.86 cm x 35.41 cm x 43.26 cm)
  • Panel mount: 8.25 in x 16.50 in x 17.03 in (20.96 cm x 41.91 cm x 43.26 cm)
  • Weatherproof: 22.23 in x 16.23 in x 9.48 in (56.46 cm x 41.22 cm x 24.08 cm)
  • Explosion-proof: Consult factory

Moisture Measurement

Type GE Moisture Image Series, TF, and M Series thin-film aluminum oxide probes
Calibration Ranges (Dew/Frost Point)
  • Standard: 68°F to -112°F (20°C to –80°C) with data to -166°F (–110°C)
  • Ultralow: -58°F to -148°F (–50° to –100°C) with data to -166°F (–110°C)
  • Extended high: 140°F to -112°F (60°C to –80°C) with data to -166°F (–110°C)
Accuracy (Dew/Frost Point)
  • ±1.1°F (±2°C) from 140°F to -85°F (60°C to –65°C)
  • ±1.6°F (±3°C) from -87°F to -166°F (–66°C to –110°C)
Repeatability (Dew/Frost Point)
  • ±0.3°F (±0.5°C) from 140°F to -85°F (60°C to –65°C)
  • ±0.5°F (±1.0°C) from -87°F to -166°F (–66°C to –110°C)
Operating Pressure 5 of Hg to 5000 psig (345 bar) limited by optional pressure sensor—see pressure sensor ranges
Other Moisture Parameters Relative humidity (RH), parts per million by volume (ppmv), parts per million by weight (ppmw), parts per billion by volume (ppbv), pounds per million standard cubic feet (lb/MMSCF)

Temperature Measurement

Type Optional thermistor built into moisture probe
Range –22°F to 158°F (–30°C to 70°C)
Accuracy ±0.3°F (±0.5°C) at –22°F (–30°C)

Pressure Measurement

Type Optional transducer built into TF and Moisture Image Series moisture probes or standard external pressure transmitter, 24 V, 4 to 20 mA
Range 0 to 5000 psig (1 to 345 bar); specify type and pressure range
Accuracy ±1% of full scale
Pressure Rating Three times the span of the available range to a maximum of 7500 psig (518 bar)

 

Oxygen Measurement


Optional nondepleting electrolytic oxygen sensor.
Additional details and specifications are available on request. 

Download

Descriptions 中文 Dutch English Français Deutsch Italiano 日本語 Polish Português Russian Español
MIS 1 Bench-Mount Package Drawing acrobat-reader
MIS 1 Panel-Mount Package Drawing acrobat-reader
MMS 3 Weatherproof Package Drawing acrobat-reader
BASEEFA System Drawing for MIS 1 IS System acrobat-reader acrobat-reader acrobat-reader
BASEEFA System Drawing for MMS 3 IS System acrobat-reader
Basic Hygrometry Principles acrobat-reader
CSA-NRTL System Drawing for MIS 1 IS System acrobat-reader
M Series Moisture Probe acrobat-reader acrobat-reader acrobat-reader acrobat-reader acrobat-reader
MIS 1 Bench-Mount Package Drawing acrobat-reader acrobat-reader
MIS 1 Interconnection Drawing for Rack, Bench & Panel acrobat-reader
MIS 1 Panel-Mount Package Drawing acrobat-reader acrobat-reader
MIS 1 Rack-Mount Package Drawing acrobat-reader acrobat-reader
MIS 1 Weatherproof Package Drawing acrobat-reader
MIS Probe 2 Aluminum Oxide Moisture Probe Brochure acrobat-reader
MIS1 (w/703-1250 Controller Board) acrobat-reader
MIS1 (w/703-1250 Controller Board) Service acrobat-reader
MIS1 Hygrometer Operating Manual acrobat-reader acrobat-reader acrobat-reader acrobat-reader acrobat-reader acrobat-reader acrobat-reader acrobat-reader acrobat-reader
MIS1 Quick Start acrobat-reader
MMS 3 Bench-Mount Package Drawing acrobat-reader
MMS 3 Interconnection Drawing for Rack, Bench & Panel acrobat-reader
MMS 3 Interconnection Drawing for Weatherproof Package acrobat-reader
MMS 3 Panel-Mount Package Drawing acrobat-reader
MMS 3 Rack-Mount Package Drawing acrobat-reader
Moisture Image Series 1 Analisador de Umidade da Panametrics acrobat-reader
Moisture Image Series 1 Analizzatore di umidita Panametrics acrobat-reader
Moisture Image Series 1 Brochure acrobat-reader acrobat-reader acrobat-reader
Moisture Series acrobat-reader
Nondepleting Oxygen Cell acrobat-reader acrobat-reader acrobat-reader acrobat-reader
Three-Function Moisture Probe acrobat-reader acrobat-reader acrobat-reader acrobat-reader
Weatherproof Package Drawing acrobat-reader

Click here to download MIS-1 Updates

acrobat-reader