Electro-chemically active elements, such as excess oxygen, dissolved in the coolant stream can cause inter-granular stress corrosion cracking (IGSCC) in the reactor vessel and piping systems. This can result in additional outage time and increased costs for reactor internal replacements or repairs. The initiation of IGSCC can be mitigated by both injecting hydrogen to neutralize the free oxygen and by monitoring the electrochemical corrosion potential (ECP) in various locations.

GE recommends that BWRs use detectors that accurately monitor ECP when hydrogen injection is turned off, as well as when hydrogen is being injected. At present, many plants utilize a system that can monitor data from two different types of probes:

  • An iron/ iron oxide ECP probe for measurements without hydrogen injection
  • A platinum ECP probe for measurements during hydrogen injection.

Additional ECP probes have been designed and manufactured for special applications, such as stainless steel and carbon steel. If you have a special request please, contact your local GE representative.

 

Specifications

  • Design Pressure: 1250 psig
  • Design Temperature: 300°C
  • Temp Ramp rate: 3°C/min
  • Insulation resistance > 1 x 108 ohms with 9 ± 1 VDC applied, prior to installation.

Contact Us

Contact TypeContact Information
Application Engineering Jeff Parmelee
Tel:(330) 963-2499
Mobile: (330) 289 5646
E-mail: jeff.parmelee@ge.com
Global Sales (Excluding Asia) Bill Kanda
Tel: Tel (330) 963-2315
Mobile: (330)-401-9497
E-mail: william.kanda@ge.com

Dan Waltermire
Tel: (910) 819-1818
Mobile: (910)-200-9859
E-mail: dan.waltermire@ge.com
Global Sales (Asia) Masaki Urushihara
Tel: 81-3-5544-3815
Mobile: 81-80-3080-7080